Subodh Trading Company Logo

Quick Searches

Quote Cart

0 items selected

Hypersil Columns

Hypersil GOLD aQ

The Thermo Fisher™ Hypersil GOLD™ aQ column is a polar endcapped C18 reversed-phase HPLC column built on 1.9, 3, and 5 µm particle sizes — engineered to deliver a controlled interaction mechanism by which polar analytes can be retained and resolved using highly aqueous to fully aqueous mobile phases. Unlike standard C18 phases that suffer phase collapse in high-aqueous conditions, the Hypersil GOLD aQ polar endcapping is designed for stable operation in 100% aqueous mobile phases — making it the correct choice for highly polar analytes that require aqueous-rich gradients for practical retention. The polar endcapped C18 chemistry provides alternative selectivity to standard C18, enabling retention and resolution of water-soluble analytes such as vitamins, polar pharmaceutical compounds, and hydrophilic small molecules that are poorly retained on conventional reversed-phase columns. Classified under USP L1 with a pore size of 175 Å, a carbon load of 12%, and a pH range of 2 to 9, Hypersil GOLD aQ is available in column lengths of 20–250 mm across 1.0, 2.1, 3.0, 4.0, and 4.6 mm internal diameters, plus preparative formats in 5 µm with internal diameters up to 50 mm.

Price
Contact for pricing

Hypersil GOLD aQ Hypersil Columns Technical Specifications and Details

Hypersil GOLD aQ — Polar Endcapped C18 for Retention of Polar Analytes in Aqueous Mobile Phases

The Aqueous Compatibility Challenge in Reversed-Phase HPLC

Standard C18 reversed-phase columns face two fundamental limitations for polar analytes: poor retention of highly hydrophilic compounds in organic-rich mobile phases, and phase collapse when highly aqueous mobile phases are used to improve that retention. The result is a difficult compromise — either the analyte elutes near the void, or the column degrades under the conditions required to retain it.

The Thermo Fisher™ Hypersil GOLD™ aQ resolves both problems through a polar endcapped C18 phase engineered to deliver a controlled interaction mechanism for polar analyte retention and resolution, with stability in 100% aqueous mobile phases. This unique combination makes Hypersil GOLD aQ the preferred choice for water-soluble vitamins, polar pharmaceutical compounds, and hydrophilic analytes that are not adequately served by standard C18 methodology.

Hypersil GOLD aQ Column — Product Image Hypersil GOLD aQ — Polar endcapped C18, USP L1, 175 Å pore size, 12% carbon load, pH 2–9. Available in 1.9, 3, and 5 µm analytical particle sizes plus 5 µm preparative format.


Key Benefits

  • Polar endcapped C18 phase — engineered for alternative selectivity and controlled retention of polar analytes
  • Retention and resolution of polar analytes — retains water-soluble compound classes that elute unretained on standard C18
  • Stable in 100% aqueous mobile phases — polar endcapping prevents phase collapse under fully aqueous conditions
  • Alternative selectivity to C18 — the polar endcapping modifies selectivity to differentiate polar analytes that co-elute on standard C18
  • Three analytical particle sizes — 1.9 µm (UHPLC), 3 µm, and 5 µm for the full range of HPLC and UHPLC workflows
  • Preparative format available — 5 µm preparative columns for scale-up purification of polar compound classes
  • USP L1 classification — supports pharmacopoeial method compliance

Chromatographic Demonstration — Water Soluble Vitamins

The chromatogram below demonstrates Hypersil GOLD aQ separating eight water-soluble vitamins — a highly polar, diverse compound class that is notoriously difficult to retain and resolve simultaneously on standard C18 columns — in a single 15-minute gradient run.

Hypersil GOLD aQ — Water Soluble Vitamins Chromatogram Hypersil GOLD aQ, 5 µm, 150 × 4.6 mm. Mobile Phase A: 50 mM KH₂PO₄, pH 3.5. Mobile Phase B: MeOH. Gradient: 0–100% B in 15 min. Flow Rate: 1 mL/min. Detection: UV 205 nm.

Peak Assignment — Water Soluble Vitamins:

Peak Analyte
1 Vitamin B1 (thiamine)
2 Vitamin B6 (pyridoxine)
3 Vitamin B3 (nicotinamide)
4 Vitamin B5 (pantothenic acid)
5 Folic Acid
6 Vitamin B12 (cyanocobalamin)
7 Vitamin H (biotin)
8 Vitamin B2 (riboflavin)

All eight water-soluble vitamins are designed to be retained and resolved in a single gradient run on Hypersil GOLD aQ — demonstrating the practical power of the polar endcapped C18 interaction mechanism for highly polar, aqueous-compatible analyte classes.


Applications

Industry / Field Application
💊 Pharmaceutical & Nutraceuticals Water-soluble vitamin assays (B1, B2, B3, B5, B6, B12, biotin, folic acid)
🌿 Food Science Polar additive, preservative, and vitamin content analysis
🔬 Bioanalysis Polar metabolite quantification, hydrophilic drug compound analysis
🧪 General Chemistry Polar analyte separations requiring aqueous-stable C18 alternative selectivity
🏭 Preparative / Purification Scale-up purification of polar compound classes using the 5 µm preparative format

Phase Property Overview

Property Value / Description
Phase Chemistry Polar endcapped C18 (aQ)
Analytical Particle Sizes 1.9 µm, 3 µm, 5 µm
Preparative Particle Size 5 µm
Pore Size 175 Å
Carbon Load 12%
pH Operating Range 2 to 9
Hydrophobicity Low to moderate (as indicated in manufacturer phase property chart)
USP Classification L1
Key Differentiator Stable in 100% aqueous mobile phases — polar endcapping prevents phase collapse

Hypersil GOLD aQ vs. Standard Hypersil GOLD C18

Feature Hypersil GOLD C18 Hypersil GOLD aQ
Phase Type Standard endcapped C18 Polar endcapped C18
Polar analyte retention Limited Enhanced via controlled interaction mechanism
100% aqueous stability No — phase collapse risk Yes — designed for fully aqueous mobile phases
Selectivity Standard C18 Alternative — optimized for polar analytes
Pore Size ~150 Å 175 Å
Carbon Load Higher 12%
Preparative format Available Available (5 µm)
USP Classification L1 L1

Column Format Overview

Format Particle Size Lengths Available Internal Diameters
UHPLC Column 1.9 µm 20, 30, 50, 100, 150, 200 mm 1.0, 2.1, 3.0, 4.6 mm
HPLC Column 3 µm 30, 50, 100, 150 mm 1.0, 2.1, 3.0, 4.0, 4.6 mm
HPLC Column 5 µm 50, 100, 150, 250 mm 2.1, 3.0, 4.6 mm
Drop-in Guard (4/pk) 3 µm 10 mm 1.0, 2.1, 3.0, 4.0, 4.6 mm
Drop-in Guard (4/pk) 5 µm 10 mm 2.1, 3.0, 4.6 mm
Preparative HPLC Column 5 µm 100, 150, 250 mm 10, 20, 30, 50 mm
Preparative Guard Cartridge (3/pk) 5 µm 10 mm 20 mm
Uniguard Drop-in Guard Cartridge Holder 10 mm 1.0, 2.1, 3.0, 4.0, 4.6 mm

Hypersil GOLD aQ — Variants & Ordering Guide

Hypersil GOLD aQ is available in three analytical particle sizes — 1.9, 3, and 5 µm — plus a 5 µm preparative format, across a comprehensive range of column lengths and internal diameters.

Hypersil GOLD aQ Column Formats


Particle Size: 1.9 µm — UHPLC Column

Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.0 mm ID 4.6 mm ID
20 25302-022130
30 25302-032130
50 25302-051030 25302-052130 25302-053030 25302-054630
100 25302-101030 25302-102130 25302-103030
150 25302-152130
200 25302-202130

Particle Size: 3 µm — Drop-in Guard (4/pk) & HPLC Column

Format Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.0 mm ID 4.6 mm ID
Drop-in Guard (4/pk) 10 25303-011001 25303-012101 25303-013001 25303-014001 25303-014001
HPLC Column 30 25303-032130
HPLC Column 50 25303-051030 25303-052130 25303-053030 25303-054030 25303-054630
HPLC Column 100 25303-101030 25303-102130 25303-103030 25303-104030 25303-104630
HPLC Column 150 25303-151030 25303-152130 25303-153030 25303-154030 25303-154630

Particle Size: 5 µm — Drop-in Guard (4/pk) & HPLC Column

Format Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.0 mm ID 4.6 mm ID
Drop-in Guard (4/pk) 10 25305-012101 25305-013001 25305-014001
HPLC Column 50 25305-052130 25305-053030 25305-054630
HPLC Column 100 25305-102130 25305-103030 25305-104630
HPLC Column 150 25305-152130 25305-153030 25305-154630
HPLC Column 250 25305-252130 25305-253030 25305-254630

Uniguard Drop-in Guard Cartridge Holder

Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.0 mm ID 4.6 mm ID
10 851-00 852-00 852-00 850-00 850-00

Preparative Format — Particle Size: 5 µm

Preparative Guard Cartridge (3/pk)

Length (mm) 10 mm ID 20 mm ID 30 mm ID 50 mm ID
10 25305-019023A

Preparative HPLC Column

Length (mm) 10 mm ID 20 mm ID 30 mm ID 50 mm ID
100 25305-109070A 25305-109370A 25305-109570A
150 25305-159070A 25305-159270A 25305-159370A 25305-159570A
250 25305-259070A 25305-259270A 25305-259370A 25305-259570A

Dashes (—) indicate that format/dimension combination is not listed in current product literature.


📧 Subodh Trading Company — Authorized Thermo Fisher Distributor, Maharashtra > sales@subodhtrading.com

Technical Specifications — Hypersil GOLD aQ

Phase & Chemical Properties

Property Value / Description
Phase Chemistry Polar endcapped C18 (aQ)
Analytical Particle Sizes 1.9 µm, 3 µm, 5 µm
Preparative Particle Size 5 µm
Pore Size 175 Å
Carbon Load 12%
pH Operating Range 2 to 9
Hydrophobicity Low to moderate (as indicated in manufacturer phase property chart)
USP Classification L1
Aqueous Stability Stable in 100% aqueous mobile phases — polar endcapping prevents phase collapse

Hypersil GOLD aQ Phase Properties


Demonstrated Method Conditions — Water Soluble Vitamins Application

Parameter Value
Column Hypersil GOLD aQ, 5 µm, 150 × 4.6 mm
Mobile Phase A 50 mM KH₂PO₄, pH 3.5
Mobile Phase B MeOH
Gradient 0–100% B in 15 min
Flow Rate 1 mL/min
Detection UV, 205 nm
Analytes Vitamin B1 (thiamine), Vitamin B6 (pyridoxine), Vitamin B3 (nicotinamide), Vitamin B5 (pantothenic acid), Folic Acid, Vitamin B12 (cyanocobalamin), Vitamin H (biotin), Vitamin B2 (riboflavin)

Conditions taken directly from manufacturer application chromatogram legend. Not intended as universal method recommendations for all sample types or instruments.


Column Dimensions Reference — 1.9 µm UHPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25302-022130 UHPLC Column 20 2.1 1.9 aQ
25302-032130 UHPLC Column 30 2.1 1.9 aQ
25302-051030 UHPLC Column 50 1.0 1.9 aQ
25302-052130 UHPLC Column 50 2.1 1.9 aQ
25302-053030 UHPLC Column 50 3.0 1.9 aQ
25302-054630 UHPLC Column 50 4.6 1.9 aQ
25302-101030 UHPLC Column 100 1.0 1.9 aQ
25302-102130 UHPLC Column 100 2.1 1.9 aQ
25302-103030 UHPLC Column 100 3.0 1.9 aQ
25302-152130 UHPLC Column 150 2.1 1.9 aQ
25302-202130 UHPLC Column 200 2.1 1.9 aQ

Column Dimensions Reference — 3 µm HPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25303-011001 Drop-in Guard (4/pk) 10 1.0 3 aQ
25303-012101 Drop-in Guard (4/pk) 10 2.1 3 aQ
25303-013001 Drop-in Guard (4/pk) 10 3.0 3 aQ
25303-014001 Drop-in Guard (4/pk) 10 4.0 / 4.6 3 aQ
25303-032130 HPLC Column 30 2.1 3 aQ
25303-051030 HPLC Column 50 1.0 3 aQ
25303-052130 HPLC Column 50 2.1 3 aQ
25303-053030 HPLC Column 50 3.0 3 aQ
25303-054030 HPLC Column 50 4.0 3 aQ
25303-054630 HPLC Column 50 4.6 3 aQ
25303-101030 HPLC Column 100 1.0 3 aQ
25303-102130 HPLC Column 100 2.1 3 aQ
25303-103030 HPLC Column 100 3.0 3 aQ
25303-104030 HPLC Column 100 4.0 3 aQ
25303-104630 HPLC Column 100 4.6 3 aQ
25303-151030 HPLC Column 150 1.0 3 aQ
25303-152130 HPLC Column 150 2.1 3 aQ
25303-153030 HPLC Column 150 3.0 3 aQ
25303-154030 HPLC Column 150 4.0 3 aQ
25303-154630 HPLC Column 150 4.6 3 aQ

Column Dimensions Reference — 5 µm HPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25305-012101 Drop-in Guard (4/pk) 10 2.1 5 aQ
25305-013001 Drop-in Guard (4/pk) 10 3.0 5 aQ
25305-014001 Drop-in Guard (4/pk) 10 4.6 5 aQ
25305-052130 HPLC Column 50 2.1 5 aQ
25305-053030 HPLC Column 50 3.0 5 aQ
25305-054630 HPLC Column 50 4.6 5 aQ
25305-102130 HPLC Column 100 2.1 5 aQ
25305-103030 HPLC Column 100 3.0 5 aQ
25305-104630 HPLC Column 100 4.6 5 aQ
25305-152130 HPLC Column 150 2.1 5 aQ
25305-153030 HPLC Column 150 3.0 5 aQ
25305-154630 HPLC Column 150 4.6 5 aQ
25305-252130 HPLC Column 250 2.1 5 aQ
25305-253030 HPLC Column 250 3.0 5 aQ
25305-254630 HPLC Column 250 4.6 5 aQ

Column Dimensions Reference — Preparative (5 µm)

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25305-019023A Prep Guard Cartridge (3/pk) 10 20 5 aQ
25305-109070A Prep HPLC Column 100 10 5 aQ
25305-109370A Prep HPLC Column 100 20 5 aQ
25305-109570A Prep HPLC Column 100 50 5 aQ
25305-159070A Prep HPLC Column 150 10 5 aQ
25305-159270A Prep HPLC Column 150 20 5 aQ
25305-159370A Prep HPLC Column 150 30 5 aQ
25305-159570A Prep HPLC Column 150 50 5 aQ
25305-259070A Prep HPLC Column 250 10 5 aQ
25305-259270A Prep HPLC Column 250 20 5 aQ
25305-259370A Prep HPLC Column 250 30 5 aQ
25305-259570A Prep HPLC Column 250 50 5 aQ

⚠️ Specifications and performance data presented here are based on publicly available manufacturer literature. Performance may vary based on application conditions, instrument configuration, and sample matrix. For method-specific guidance, contact Subodh Trading Company at sales@subodhtrading.com — authorized Thermo Fisher distributor for Maharashtra.

FAQs — Hypersil GOLD aQ Column


Q: What is the Hypersil GOLD aQ column and what is it used for?

Hypersil GOLD aQ is a polar endcapped C18 reversed-phase HPLC column engineered to retain and resolve polar analytes through a controlled interaction mechanism, with stability in 100% aqueous mobile phases. It is designed for water-soluble vitamins, polar pharmaceutical compounds, hydrophilic metabolites, and any application requiring aqueous-stable C18 alternative selectivity for highly polar compound classes.


Q: What does "aQ" mean and how does the polar endcapping work?

The "aQ" designation refers to the aqueous-compatible polar endcapping of the C18 bonded phase. The polar endcapping modifies the surface chemistry to prevent phase collapse under fully aqueous mobile phase conditions — a common failure mode for standard C18 columns — while simultaneously providing a controlled interaction mechanism that retains and resolves polar analytes that would otherwise elute unretained on a standard C18 phase.


Q: How is Hypersil GOLD aQ different from standard Hypersil GOLD C18?

Hypersil GOLD aQ uses a polar endcapped C18 chemistry rather than a standard endcapped C18. This delivers two key differences: it is stable in 100% aqueous mobile phases where standard C18 would collapse, and it provides alternative selectivity for polar analytes through a controlled polar interaction mechanism. The pore size is also larger at 175 Å vs. ~150 Å, and the carbon load is 12%.


Q: Is Hypersil GOLD aQ stable in 100% aqueous mobile phases?

Yes. Hypersil GOLD aQ is specifically engineered for stable operation in 100% aqueous mobile phases. The polar endcapping prevents the phase collapse that affects conventional C18 columns under fully aqueous conditions — making it reliable for the highly aqueous gradients required to retain very polar analytes.


Q: What analytes were demonstrated in the water-soluble vitamins chromatogram?

Eight water-soluble vitamins were separated in a single 15-minute gradient run: Vitamin B1 (thiamine), Vitamin B6 (pyridoxine), Vitamin B3 (nicotinamide), Vitamin B5 (pantothenic acid), Folic Acid, Vitamin B12 (cyanocobalamin), Vitamin H (biotin), and Vitamin B2 (riboflavin). All conditions are sourced directly from the manufacturer's application chromatogram legend.


Q: What method conditions were used in the water-soluble vitamins application?

Column — Hypersil GOLD aQ, 5 µm, 150 × 4.6 mm; Mobile Phase A — 50 mM KH₂PO₄, pH 3.5; Mobile Phase B — MeOH; Gradient — 0–100% B in 15 min; Flow Rate — 1 mL/min; Detection — UV 205 nm. All values are sourced directly from the manufacturer's application chromatogram legend.


Q: What particle sizes and formats are available for Hypersil GOLD aQ?

Analytical columns are available in 1.9 µm (UHPLC), 3 µm, and 5 µm particle sizes. Preparative columns are available in 5 µm particle size with internal diameters of 10, 20, 30, and 50 mm — enabling direct scale-up from analytical to preparative format within the same polar endcapped C18 phase chemistry.


Q: What USP classification does Hypersil GOLD aQ carry?

Hypersil GOLD aQ is classified under USP L1, as stated in the manufacturer's product literature. Despite the polar endcapping modification, the primary phase chemistry remains C18, supporting use in pharmacopoeial methods specifying a USP L1 stationary phase.


Q: What are the pore size and carbon load of Hypersil GOLD aQ?

Hypersil GOLD aQ has a pore size of 175 Å and a carbon load of 12%, as stated in the manufacturer's product literature. The 175 Å pore size is larger than the ~150 Å pore of the standard Hypersil GOLD C18 and C8 phases.


Q: What pH range does Hypersil GOLD aQ operate within?

Hypersil GOLD aQ is designed to operate across a pH range of 2 to 9, as indicated in the manufacturer's phase property chart. Always refer to the column care and use instructions supplied with your column for precise operating limits.


Q: What column lengths and internal diameters are available for Hypersil GOLD aQ analytical columns?

The 1.9 µm UHPLC format is available in 20–200 mm lengths across 1.0, 2.1, 3.0, and 4.6 mm ID. The 3 µm format covers 30–150 mm lengths across 1.0, 2.1, 3.0, 4.0, and 4.6 mm ID. The 5 µm format covers 50–250 mm lengths across 2.1, 3.0, and 4.6 mm ID. See the Variants & Ordering tab for the complete part number matrix.


Q: Is a guard column available for Hypersil GOLD aQ?

Yes. Drop-in Guard cartridges (4/pk, 10 mm) are available for 3 µm and 5 µm columns across multiple ID formats. Uniguard Drop-in Guard Cartridge Holders are available: 851-00 (1.0 mm ID), 852-00 (2.1 mm / 3.0 mm ID), and 850-00 (4.0 mm / 4.6 mm ID). A preparative guard cartridge (25305-019023A, 3/pk) is also available for the 5 µm preparative format.


Q: Where can I buy Hypersil GOLD aQ columns in Maharashtra?

Hypersil GOLD aQ columns are available in Maharashtra through Subodh Trading Company, the authorized Thermo Fisher distributor for Maharashtra. Subodh Trading Company supplies genuine Thermo Fisher products with full warranty and Certificate of Analysis, serving laboratories across Pune, Nagpur, Nashik, Aurangabad, Chhatrapati Sambhaji Nagar, Solapur, Sangli, Kolhapur, Satara, Ahmednagar, Jalgaon, Nanded, Amravati, Akola, Latur, Ratnagiri, Thane, and all of Maharashtra. Contact: sales@subodhtrading.com.


Q: How do I obtain a Certificate of Analysis for my Hypersil GOLD aQ column?

A Certificate of Analysis is available for every Hypersil GOLD aQ column by part number and lot number from the Thermo Fisher CoA search portal at thermofisher.com. Subodh Trading Company can also assist customers in Maharashtra — email sales@subodhtrading.com with your purchase details or column lot number.

Have a question?