Subodh Trading Company Logo

Quick Searches

Quote Cart

0 items selected

Hypersil Columns

Hypersil GOLD CN

The Thermo Fisher™ Hypersil GOLD™ CN column is a cyano (nitrile) bonded reversed-phase and normal-phase HPLC column built on 1.9, 3, and 5 µm particle sizes — engineered for both normal-phase and reversed-phase separations, providing alternative selectivity with lower hydrophobicity than standard C18 or C8 phases. The cyano phase delivers a unique combination of dipole-dipole, pi-pi, and hydrophobic interaction mechanisms that provides alternative selectivity to alkyl phases — making it a powerful orthogonal selectivity tool for complex mixtures where standard reversed-phase methods reach their resolution limits. With lower hydrophobicity, compounds elute faster for quicker analysis, while the Hypersil GOLD ultra-pure silica platform ensures excellent peak shape and outstanding sensitivity throughout. Classified under USP L10 with a pore size of 175 Å, a carbon load of 4%, and a pH range of 2 to 8, available in column lengths of 50–250 mm across 1.0, 2.1, 3.0, 4.0, and 4.6 mm internal diameters.

Price
Contact for pricing

Hypersil GOLD CN Hypersil Columns Technical Specifications and Details

Hypersil GOLD CN — Cyano Phase for Normal-Phase and Reversed-Phase Separations

One Phase — Two Operating Modes, Alternative Selectivity

The cyano (CN) stationary phase is unique among HPLC bonded phases in its ability to operate in both reversed-phase and normal-phase modes — giving analysts flexibility that no single alkyl phase can match. In reversed-phase mode, it provides alternative selectivity with lower hydrophobicity than C18 or C8, delivering faster analysis for compounds that are over-retained on longer-chain phases. In normal-phase mode, it retains the polar selectivity advantages of normal-phase methodology without the need for fully non-polar solvents.

The Thermo Fisher™ Hypersil GOLD™ CN combines this dual-mode capability with the ultra-pure silica platform of the Hypersil GOLD range — delivering excellent peak shape and outstanding sensitivity alongside the versatile selectivity of the cyano phase.

Hypersil GOLD CN Column — Product Image Hypersil GOLD CN — 1.9, 3, and 5 µm particle sizes, USP L10, 175 Å pore size, 4% carbon load, pH 2–8.


Key Benefits

  • Dual-mode capability — suitable for both normal-phase and reversed-phase separations from a single column
  • Alternative selectivity with lower hydrophobicity — orthogonal selectivity to C18 and C8 for complex mixture resolution
  • Less retention for faster analysis — lower carbon load (4%) and hydrophobicity means compounds elute more quickly than on C18
  • Excellent peak shape — Hypersil GOLD ultra-pure silica endcapping ensures sharp, symmetrical peaks
  • Outstanding sensitivity — narrow, well-shaped peaks deliver improved S/N and lower detection limits
  • Three particle sizes — 1.9 µm (UHPLC), 3 µm, and 5 µm for the full range of HPLC and UHPLC workflows
  • USP L10 classification — supports pharmacopoeial method compliance

Hypersil GOLD CN vs. C18 — When to Choose CN

Feature Hypersil GOLD C18 Hypersil GOLD CN
Operating mode Reversed phase only Reversed phase AND normal phase
Hydrophobicity High Low
Retention for over-retained analytes Excessive Reduced — faster analysis
Selectivity mechanism Hydrophobic Dipole-dipole + pi-pi + hydrophobic
Carbon load Higher 4%
USP Classification L1 L10
Orthogonal selectivity vs. C18 Reference Yes — alternative selectivity

Chromatographic Demonstration — Organic Acids

The chromatogram below demonstrates Hypersil GOLD CN separating five structurally related organic acid analytes — substituted benzoic acids — a compound class where selectivity differences between isomers are subtle and phase selectivity is critical for resolution.

Hypersil GOLD CN — Organic Acids Chromatogram Hypersil GOLD CN, 5 µm, 150 × 4.6 mm. Mobile Phase A: 25 mM KH₂PO₄, pH 2. Mobile Phase B: MeOH. Temperature: 25°C. Flow Rate: 1.5 mL/min. Detection: UV 230 nm.

Peak Assignment — Organic Acids:

Peak Analyte
1 4-Fluorobenzoic acid
2 o-Toluic Acid
3 p-Toluic Acid
4 2,4,6-Trimethylbenzoic Acid
5 2,5-Dimethylbenzoic Acid

Applications

Industry / Field Application
💊 Pharmaceutical Organic acid assays, polar pharmaceutical impurity profiling, normal-phase drug compound separations
🌿 Food Science Organic acid and preservative analysis
🔬 General Chemistry Isomeric substituted aromatic acid separations; orthogonal reversed-phase method development
🧪 Normal-Phase Applications Any application requiring normal-phase selectivity without fully non-polar solvent systems
🧬 Bioanalysis Polar drug metabolite and organic acid quantification

Phase Property Overview

Property Value / Description
Phase Chemistry Cyano (CN) — nitrile bonded phase
Particle Sizes 1.9 µm, 3 µm, 5 µm
Pore Size 175 Å
Carbon Load 4%
pH Operating Range 2 to 8
Hydrophobicity Low (as indicated in manufacturer phase property chart)
Operating Modes Reversed phase and normal phase
USP Classification L10
Key Differentiator Dual-mode capability; alternative selectivity with lower hydrophobicity than C18/C8

Column Format Overview

Format Particle Size Lengths Available Internal Diameters
UHPLC Column 1.9 µm 50, 100, 150, 200 mm 2.1 mm
HPLC Column 3 µm 50, 100, 150 mm 1.0, 2.1, 3.0, 4.6 mm
HPLC Column 5 µm 50, 100, 150, 250 mm 2.1, 3.0, 4.0, 4.6 mm
Drop-in Guard (4/pk) 3 µm 10 mm 1.0, 2.1, 3.0, 4.6 mm
Drop-in Guard (4/pk) 5 µm 10 mm 2.1, 3.0, 4.0, 4.6 mm
Uniguard Drop-in Guard Cartridge Holder 10 mm 1.0, 2.1, 3.0, 4.0, 4.6 mm

Hypersil GOLD CN — Variants & Ordering Guide

Hypersil GOLD CN is available in three analytical particle sizes — 1.9, 3, and 5 µm — across a range of column lengths and internal diameters, plus Drop-in Guard and Uniguard accessories.

Hypersil GOLD CN Column Formats


Particle Size: 1.9 µm — UHPLC Column

Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.0 mm ID 4.6 mm ID
50 25802-052130
100 25802-102130
150 25802-152130
200 25802-202130

Particle Size: 3 µm — Drop-in Guard (4/pk) & HPLC Column

Format Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.0 mm ID 4.6 mm ID
Drop-in Guard (4/pk) 10 25803-011001 25803-012101 25803-013001 25803-014001
HPLC Column 50 25803-052130
HPLC Column 100 25803-101030 25803-102130 25803-103030 25803-104630
HPLC Column 150 25803-151030 25803-152130 25803-153030 25803-154630

Particle Size: 5 µm — Drop-in Guard (4/pk) & HPLC Column

Format Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.0 mm ID 4.6 mm ID
Drop-in Guard (4/pk) 10 25805-012101 25805-013001 25805-014001 25805-014001
HPLC Column 50 25805-052130 25805-053030 25805-054630
HPLC Column 100 25805-102130 25805-103030 25805-104630
HPLC Column 150 25805-152130 25805-154630
HPLC Column 250 25805-254030 25805-254630

Uniguard Drop-in Guard Cartridge Holder

Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.0 mm ID 4.6 mm ID
10 851-00 852-00 852-00 850-00 850-00

Dashes (—) indicate that format/dimension combination is not listed in current product literature.


📧 Subodh Trading Company — Authorized Thermo Fisher Distributor, Maharashtra > sales@subodhtrading.com

Technical Specifications — Hypersil GOLD CN

Phase & Chemical Properties

Property Value / Description
Phase Chemistry Cyano (CN) — nitrile bonded phase
Particle Sizes 1.9 µm, 3 µm, 5 µm
Pore Size 175 Å
Carbon Load 4%
pH Operating Range 2 to 8
Hydrophobicity Low (as indicated in manufacturer phase property chart)
Operating Modes Reversed phase and normal phase
USP Classification L10

Hypersil GOLD CN Phase Properties


Demonstrated Method Conditions — Organic Acids Application

Parameter Value
Column Hypersil GOLD CN, 5 µm, 150 × 4.6 mm
Mobile Phase A 25 mM KH₂PO₄, pH 2
Mobile Phase B MeOH
Temperature 25°C
Flow Rate 1.5 mL/min
Detection UV, 230 nm
Analytes 1. 4-Fluorobenzoic acid, 2. o-Toluic Acid, 3. p-Toluic Acid, 4. 2,4,6-Trimethylbenzoic Acid, 5. 2,5-Dimethylbenzoic Acid

Conditions taken directly from manufacturer application chromatogram legend. Not intended as universal method recommendations for all sample types or instruments.


Column Dimensions Reference — 1.9 µm UHPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25802-052130 UHPLC Column 50 2.1 1.9 CN
25802-102130 UHPLC Column 100 2.1 1.9 CN
25802-152130 UHPLC Column 150 2.1 1.9 CN
25802-202130 UHPLC Column 200 2.1 1.9 CN

Column Dimensions Reference — 3 µm HPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25803-011001 Drop-in Guard (4/pk) 10 1.0 3 CN
25803-012101 Drop-in Guard (4/pk) 10 2.1 3 CN
25803-013001 Drop-in Guard (4/pk) 10 3.0 3 CN
25803-014001 Drop-in Guard (4/pk) 10 4.6 3 CN
25803-052130 HPLC Column 50 2.1 3 CN
25803-101030 HPLC Column 100 1.0 3 CN
25803-102130 HPLC Column 100 2.1 3 CN
25803-103030 HPLC Column 100 3.0 3 CN
25803-104630 HPLC Column 100 4.6 3 CN
25803-151030 HPLC Column 150 1.0 3 CN
25803-152130 HPLC Column 150 2.1 3 CN
25803-153030 HPLC Column 150 3.0 3 CN
25803-154630 HPLC Column 150 4.6 3 CN

Column Dimensions Reference — 5 µm HPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25805-012101 Drop-in Guard (4/pk) 10 2.1 5 CN
25805-013001 Drop-in Guard (4/pk) 10 3.0 5 CN
25805-014001 Drop-in Guard (4/pk) 10 4.0 / 4.6 5 CN
25805-052130 HPLC Column 50 2.1 5 CN
25805-053030 HPLC Column 50 3.0 5 CN
25805-054630 HPLC Column 50 4.6 5 CN
25805-102130 HPLC Column 100 2.1 5 CN
25805-103030 HPLC Column 100 3.0 5 CN
25805-104630 HPLC Column 100 4.6 5 CN
25805-152130 HPLC Column 150 2.1 5 CN
25805-154630 HPLC Column 150 4.6 5 CN
25805-254030 HPLC Column 250 4.0 5 CN
25805-254630 HPLC Column 250 4.6 5 CN

Uniguard Drop-in Guard Cartridge Holder

Cat. No. Length (mm) ID
851-00 10 1.0 mm
852-00 10 2.1 mm / 3.0 mm
850-00 10 4.0 mm / 4.6 mm

⚠️ Specifications and performance data presented here are based on publicly available manufacturer literature. Performance may vary based on application conditions, instrument configuration, and sample matrix. For method-specific guidance, contact Subodh Trading Company at sales@subodhtrading.com — authorized Thermo Fisher distributor for Maharashtra.

FAQs — Hypersil GOLD CN Column


Q: What is the Hypersil GOLD CN column and what is it used for?

Hypersil GOLD CN is a cyano (nitrile) bonded HPLC column engineered for both normal-phase and reversed-phase separations, providing alternative selectivity with lower hydrophobicity than C18 or C8. It is designed for organic acid analysis, substituted aromatic compound separations, polar pharmaceutical impurity profiling, and any application where lower hydrophobicity, dual-mode capability, or orthogonal selectivity to C18 is required.


Q: Can Hypersil GOLD CN be used in both reversed-phase and normal-phase modes?

Yes. Hypersil GOLD CN is designed for both normal-phase and reversed-phase separations — a key advantage over standard alkyl phases which are restricted to reversed-phase operation. In reversed-phase mode it provides alternative selectivity with lower hydrophobicity; in normal-phase mode it retains polar compound selectivity without requiring fully non-polar solvent systems.


Q: How does the selectivity of Hypersil GOLD CN differ from C18?

Hypersil GOLD CN provides alternative selectivity to C18 through a combination of dipole-dipole interaction, pi-pi interaction, and reduced hydrophobic retention. The cyano group introduces polar interaction mechanisms absent in pure alkyl phases — meaning compounds that co-elute on C18 may be resolved on CN, and the elution order may differ. The low carbon load (4%) also means analytes elute faster than on C18, shortening run times.


Q: What analytes were demonstrated in the organic acids application chromatogram?

Five substituted benzoic acid analytes were separated: 4-Fluorobenzoic acid, o-Toluic Acid, p-Toluic Acid, 2,4,6-Trimethylbenzoic Acid, and 2,5-Dimethylbenzoic Acid — on Hypersil GOLD CN, 5 µm, 150 × 4.6 mm under isocratic reversed-phase conditions. All conditions are sourced directly from the manufacturer's application chromatogram legend.


Q: What method conditions were used in the organic acids chromatogram?

Column — Hypersil GOLD CN, 5 µm, 150 × 4.6 mm; Mobile Phase A — 25 mM KH₂PO₄, pH 2; Mobile Phase B — MeOH; Temperature — 25°C; Flow Rate — 1.5 mL/min; Detection — UV 230 nm; Analytes — 4-Fluorobenzoic acid, o-Toluic Acid, p-Toluic Acid, 2,4,6-Trimethylbenzoic Acid, 2,5-Dimethylbenzoic Acid. All values are sourced directly from the manufacturer's application chromatogram legend.


Q: What USP classification does Hypersil GOLD CN carry?

Hypersil GOLD CN is classified under USP L10, as stated in the manufacturer's product literature. This supports its use in pharmacopoeial methods and regulated laboratory workflows specifying a USP L10 cyano stationary phase.


Q: What are the pore size, carbon load, and pH range of Hypersil GOLD CN?

Hypersil GOLD CN has a pore size of 175 Å, a carbon load of 4%, and a pH operating range of 2 to 8, as stated in the manufacturer's product literature. The low 4% carbon load contributes to the lower hydrophobicity and faster elution characteristics of the CN phase. Always refer to the column care and use instructions supplied with your column for precise operating limits.


Q: What particle sizes are available for Hypersil GOLD CN?

Hypersil GOLD CN is available in three analytical particle sizes: 1.9 µm (UHPLC format), 3 µm (HPLC), and 5 µm (HPLC) — covering fast UHPLC methods through to standard analytical HPLC separations.


Q: What column lengths and internal diameters are available for Hypersil GOLD CN?

The 1.9 µm UHPLC format is available in 50–200 mm lengths in 2.1 mm ID only. The 3 µm format covers 50–150 mm lengths across 1.0, 2.1, 3.0, and 4.6 mm ID. The 5 µm format covers 50–250 mm lengths across 2.1, 3.0, 4.0, and 4.6 mm ID. Not all combinations are available for every particle size — see the Variants & Ordering tab for the complete matrix.


Q: Is a guard column available for Hypersil GOLD CN?

Yes. Drop-in Guard cartridges (4/pk, 10 mm) are available for 3 µm columns in 1.0, 2.1, 3.0, and 4.6 mm ID, and for 5 µm columns in 2.1, 3.0, 4.0, and 4.6 mm ID. Uniguard Drop-in Guard Cartridge Holders are available: 851-00 (1.0 mm ID), 852-00 (2.1 mm / 3.0 mm ID), and 850-00 (4.0 mm / 4.6 mm ID).


Q: Can Hypersil GOLD CN be used as an orthogonal selectivity column alongside C18?

Yes. Hypersil GOLD CN provides orthogonal selectivity to C18 through its combined dipole-dipole, pi-pi, and hydrophobic interaction mechanisms. For complex mixtures where C18 co-elutes compounds, CN often resolves the co-eluting pairs due to its different interaction profile. Its dual reversed-phase and normal-phase capability also allows direct comparison of both modes within a single method development workflow.


Q: Where can I buy Hypersil GOLD CN columns in Maharashtra?

Hypersil GOLD CN columns are available in Maharashtra through Subodh Trading Company, the authorized Thermo Fisher distributor for Maharashtra. Subodh Trading Company supplies genuine Thermo Fisher products with full warranty and Certificate of Analysis, serving laboratories across Pune, Nagpur, Nashik, Aurangabad, Chhatrapati Sambhaji Nagar, Solapur, Sangli, Kolhapur, Satara, Ahmednagar, Jalgaon, Nanded, Amravati, Akola, Latur, Ratnagiri, Thane, and all of Maharashtra. Contact: sales@subodhtrading.com.


Q: How do I obtain a Certificate of Analysis for my Hypersil GOLD CN column?

A Certificate of Analysis is available for every Hypersil GOLD CN column by part number and lot number from the Thermo Fisher CoA search portal at thermofisher.com. Subodh Trading Company can also assist customers in Maharashtra — email sales@subodhtrading.com with your purchase details or column lot number.

Have a question?

Need help selecting the right Hypersil GOLD CN?