Hypersil Columns

Hypersil GOLD HILIC

The Thermo Fisher™ Hypersil GOLD™ HILIC column is a hydrophilic interaction liquid chromatography HPLC column built on 1.9, 3, and 5 µm particle sizes — engineered to retain and separate polar analytes that are problematic using reversed-phase columns, providing alternative selectivity to C18 without the need for ion-pair reagents or derivatization. The Hypersil GOLD HILIC phase delivers improved sensitivity for MS detection through the use of high-organic HILIC mobile phases that enhance ESI ionization efficiency — making it a natural fit for LC-MS/MS bioanalytical and metabolomics workflows requiring polar analyte retention. Built on the same Hypersil GOLD ultra-pure silica platform that underpins the entire range, it delivers outstanding peak shape and selectivity for polar compound classes including urea, amino acids, nucleosides, and other hydrophilic analytes that elute at or near the void volume on standard reversed-phase columns. With a pore size of 175 Å, a carbon load of 6%, and a pH range of 2 to 8, available in column lengths of 30–250 mm across 1.0, 2.1, 3.0, and 4.6 mm internal diameters.

Price
Contact for pricing

Hypersil GOLD HILIC Hypersil Columns Technical Specifications and Details

Hypersil GOLD HILIC — Retain and Resolve Polar Analytes That Reversed-Phase Cannot

The Polar Analyte Retention Problem — Addressed With HILIC Selectivity

Polar and hydrophilic analytes are the most challenging class for reversed-phase HPLC — they elute near or at the void volume on C18, making retention, resolution, and reliable quantification difficult or impossible without resorting to ion-pair reagents or derivatization. Both workarounds add method complexity, reduce MS compatibility, and compromise throughput.

Hypersil GOLD HILIC eliminates these compromises. Engineered to retain and separate polar analytes that are problematic using reversed-phase columns, it provides alternative selectivity to C18 under high-organic aqueous conditions — with improved sensitivity for MS detection, no ion-pair reagents, and no derivatization required. Built on the Hypersil GOLD ultra-pure silica platform, it delivers the outstanding peak shape and selectivity of the Hypersil GOLD range alongside the polar retention advantages of HILIC.

Hypersil GOLD HILIC Column — Product Image Hypersil GOLD HILIC — 1.9, 3, and 5 µm particle sizes, 175 Å pore size, 6% carbon load, pH 2–8.


Key Benefits

  • Retains and separates polar analytes — designed for compound classes that are problematic on reversed-phase C18 columns
  • Alternative selectivity to C18 — HILIC mode provides orthogonal retention for polar analytes co-eluting or unretained on reversed-phase
  • Improved sensitivity for MS detection — high-organic HILIC mobile phases enhance ESI desolvation and ionization efficiency
  • Alternative to ion-pair reagents or derivatization — simpler methods, cleaner MS spectra, reduced sample preparation
  • Outstanding peak shape and selectivity — Hypersil GOLD ultra-pure silica platform delivers sharp, symmetrical peaks
  • Three particle sizes — 1.9 µm (UHPLC), 3 µm, and 5 µm for the full range of HPLC and UHPLC workflows

Hypersil GOLD HILIC vs. Reversed-Phase C18

Feature Hypersil GOLD C18 Hypersil GOLD HILIC
Polar analyte retention Poor — near void volume Excellent — HILIC retention mechanism
Ion-pair reagents required Often for polar analytes Not required
Derivatization required Sometimes Not required
MS sensitivity for polar analytes Limited Improved — high-organic MP enhances ESI
Selectivity mechanism Hydrophobic Hydrophilic partitioning
Best for Non-polar to moderate analytes Highly polar and hydrophilic analytes

Chromatographic Demonstration — Urea

The chromatogram below demonstrates Hypersil GOLD HILIC retaining urea — one of the smallest, most polar organic molecules — with a sharp, symmetrical peak under HILIC conditions using high-organic mobile phase with ESI-MS detection.

Hypersil GOLD HILIC — Urea Chromatogram Hypersil GOLD HILIC, 5 µm, 150 × 4.6 mm. Mobile Phase: H₂O/MeCN (10:90) + 0.1% formic acid. Temperature: 30°C. Flow Rate: 0.6 mL/min. Injection Volume: 1 µL. Detection: +ESI.

Peak Assignment:

Peak Analyte
1 Urea

The sharp, well-retained urea peak demonstrates HILIC retention of one of the most hydrophilic organic molecules — a compound that would elute unretained at the void volume on any reversed-phase column. The +ESI detection confirms direct LC-MS compatibility of the high-organic HILIC mobile phase.


Applications

Industry / Field Application
🧬 Bioanalysis & LC-MS/MS Polar drug metabolite quantification, urea and creatinine assays, hydrophilic biomarker analysis
💊 Pharmaceutical Polar API and impurity analysis without ion-pair reagents
🔬 Metabolomics Polar and charged metabolite profiling by LC-MS
🌿 Food Science Polar additive, preservative, and amino acid analysis
🧪 General Chemistry Any application where polar analytes are unretained on C18

Phase Property Overview

Property Value / Description
Phase Chemistry HILIC — hydrophilic silica-based stationary phase
Particle Sizes 1.9 µm, 3 µm, 5 µm
Pore Size 175 Å
Carbon Load 6%
pH Operating Range 2 to 8
Hydrophobicity Low (as indicated in manufacturer phase property chart)
MS Compatibility Excellent — high-organic HILIC mobile phases improve ESI sensitivity
Key Differentiator Alternative selectivity to C18; no ion-pair or derivatization; improved MS sensitivity

Column Format Overview

Format Particle Size Lengths Available Internal Diameters
UHPLC Column 1.9 µm 50, 100, 150 mm 2.1 mm
HPLC Column 3 µm 30, 50, 100, 150 mm 1.0, 2.1, 3.0, 4.6 mm
HPLC Column 5 µm 50, 100, 150, 250 mm 2.1, 3.0, 4.6 mm
Drop-in Guard (4/pk) 3 µm 10 mm 1.0, 2.1, 3.0, 4.6 mm
Drop-in Guard (4/pk) 5 µm 10 mm 2.1, 4.6 mm
Uniguard Drop-in Guard Cartridge Holder 10 mm 1.0, 2.1, 3.0, 4.6 mm

Hypersil GOLD HILIC — Variants & Ordering Guide

Hypersil GOLD HILIC is available in three analytical particle sizes — 1.9, 3, and 5 µm — across a range of column lengths and internal diameters, plus Drop-in Guard and Uniguard accessories.

Hypersil GOLD HILIC Column Formats


Particle Size: 1.9 µm — UHPLC Column

Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.6 mm ID
50 26502-052130
100 26502-102130
150 26502-152130

Particle Size: 3 µm — Drop-in Guard (4/pk) & HPLC Column

Format Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.6 mm ID
Drop-in Guard (4/pk) 10 26503-011001 26503-012101 26503-013001 26503-014001
HPLC Column 30 26503-032130
HPLC Column 50 26503-052130
HPLC Column 100 26503-101030 26503-102130 26503-103030 26503-104630
HPLC Column 150 26503-151030 26503-152130 26503-153030 26503-154630

Particle Size: 5 µm — Drop-in Guard (4/pk) & HPLC Column

Format Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.6 mm ID
Drop-in Guard (4/pk) 10 26505-012101 26505-014001
HPLC Column 50 26505-052130 26505-054630
HPLC Column 100 26505-102130 26505-103030 26505-104630
HPLC Column 150 26503-101030 26505-154630
HPLC Column 250 26505-252130 26505-253030 26505-254630

Uniguard Drop-in Guard Cartridge Holder

Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.6 mm ID
10 851-00 852-00 852-00 850-00

Dashes (—) indicate that format/dimension combination is not listed in current product literature.


📧 Subodh Trading Company — Authorized Thermo Fisher Distributor, Maharashtra > sales@subodhtrading.com

Technical Specifications — Hypersil GOLD HILIC

Phase & Chemical Properties

Property Value / Description
Phase Chemistry HILIC — hydrophilic silica-based stationary phase
Particle Sizes 1.9 µm, 3 µm, 5 µm
Pore Size 175 Å
Carbon Load 6%
pH Operating Range 2 to 8
Hydrophobicity Low (as indicated in manufacturer phase property chart)
MS Compatibility Excellent — high-organic HILIC mobile phases designed to improve ESI ionization efficiency
Key Differentiator Alternative selectivity to C18; no ion-pair or derivatization required; improved MS sensitivity for polar analytes

Hypersil GOLD HILIC Phase Properties


Demonstrated Method Conditions — Urea Application

Parameter Value
Column Hypersil GOLD HILIC, 5 µm, 150 × 4.6 mm
Mobile Phase H₂O/MeCN (10:90) + 0.1% formic acid
Temperature 30°C
Flow Rate 0.6 mL/min
Injection Volume 1 µL
Detection +ESI
Analyte 1. Urea

Conditions taken directly from manufacturer application chromatogram legend. Not intended as universal method recommendations for all sample types or instruments.


Column Dimensions Reference — 1.9 µm UHPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
26502-052130 UHPLC Column 50 2.1 1.9 HILIC
26502-102130 UHPLC Column 100 2.1 1.9 HILIC
26502-152130 UHPLC Column 150 2.1 1.9 HILIC

Column Dimensions Reference — 3 µm HPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
26503-011001 Drop-in Guard (4/pk) 10 1.0 3 HILIC
26503-012101 Drop-in Guard (4/pk) 10 2.1 3 HILIC
26503-013001 Drop-in Guard (4/pk) 10 3.0 3 HILIC
26503-014001 Drop-in Guard (4/pk) 10 4.6 3 HILIC
26503-032130 HPLC Column 30 2.1 3 HILIC
26503-052130 HPLC Column 50 2.1 3 HILIC
26503-101030 HPLC Column 100 1.0 3 HILIC
26503-102130 HPLC Column 100 2.1 3 HILIC
26503-103030 HPLC Column 100 3.0 3 HILIC
26503-104630 HPLC Column 100 4.6 3 HILIC
26503-151030 HPLC Column 150 1.0 3 HILIC
26503-152130 HPLC Column 150 2.1 3 HILIC
26503-153030 HPLC Column 150 3.0 3 HILIC
26503-154630 HPLC Column 150 4.6 3 HILIC

Column Dimensions Reference — 5 µm HPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
26505-012101 Drop-in Guard (4/pk) 10 2.1 5 HILIC
26505-014001 Drop-in Guard (4/pk) 10 4.6 5 HILIC
26505-052130 HPLC Column 50 2.1 5 HILIC
26505-054630 HPLC Column 50 4.6 5 HILIC
26505-102130 HPLC Column 100 2.1 5 HILIC
26505-103030 HPLC Column 100 3.0 5 HILIC
26505-104630 HPLC Column 100 4.6 5 HILIC
26503-101030 HPLC Column 150 2.1 5 HILIC
26505-154630 HPLC Column 150 4.6 5 HILIC
26505-252130 HPLC Column 250 2.1 5 HILIC
26505-253030 HPLC Column 250 3.0 5 HILIC
26505-254630 HPLC Column 250 4.6 5 HILIC

Uniguard Drop-in Guard Cartridge Holder

Cat. No. Length (mm) ID
851-00 10 1.0 mm
852-00 10 2.1 mm / 3.0 mm
850-00 10 4.6 mm

⚠️ Specifications and performance data presented here are based on publicly available manufacturer literature. Performance may vary based on application conditions, instrument configuration, and sample matrix. For method-specific guidance, contact Subodh Trading Company at sales@subodhtrading.com — authorized Thermo Fisher distributor for Maharashtra.

FAQs — Hypersil GOLD HILIC Column


Q: What is the Hypersil GOLD HILIC column and what is it used for?

Hypersil GOLD HILIC is a hydrophilic interaction liquid chromatography HPLC column engineered to retain and separate polar analytes that are problematic using reversed-phase columns. It is designed for urea, amino acids, nucleosides, polar drug metabolites, and other highly hydrophilic analytes — compound classes that elute unretained near the void volume on standard C18 columns — while delivering improved sensitivity for MS detection and eliminating the need for ion-pair reagents or derivatization.


Q: How does Hypersil GOLD HILIC retain polar analytes that C18 cannot?

Hypersil GOLD HILIC operates in HILIC mode — where a water-enriched layer forms on the hydrophilic stationary phase surface under high-organic mobile phase conditions. Polar analytes partition into this water-enriched layer, generating retention that increases with analyte polarity — the opposite of reversed-phase HPLC. This mechanism retains highly hydrophilic compounds that have no affinity for the hydrophobic C18 surface.


Q: Why does Hypersil GOLD HILIC improve sensitivity for MS detection?

HILIC operation requires high-organic mobile phases — typically 80–95% acetonitrile. These high-organic conditions provide significantly more efficient desolvation in the ESI source compared to the predominantly aqueous mobile phases used in reversed-phase HPLC. More efficient desolvation leads to improved ionization efficiency, resulting in higher signal intensity for polar analytes in LC-MS and LC-MS/MS detection.


Q: What was demonstrated in the urea application chromatogram?

The application demonstrates Hypersil GOLD HILIC retaining urea — one of the most polar and hydrophilic organic molecules — with a sharp, well-retained peak using H₂O/MeCN (10:90) + 0.1% formic acid mobile phase at 0.6 mL/min, 30°C, 1 µL injection volume, with +ESI detection on a 5 µm, 150 × 4.6 mm column. All conditions are sourced directly from the manufacturer's application chromatogram legend.


Q: Is Hypersil GOLD HILIC compatible with LC-MS/MS detection?

Yes. Hypersil GOLD HILIC is specifically noted for improved sensitivity for MS detection. The high-organic HILIC mobile phase is fully compatible with positive and negative ESI ionization — the urea application chromatogram uses +ESI detection directly, confirming LC-MS compatibility without mobile phase switching or post-column modification.


Q: Does Hypersil GOLD HILIC require ion-pair reagents for polar analyte retention?

No. One of the key advantages of Hypersil GOLD HILIC is that it provides an alternative to ion-pair chromatography for polar analyte retention. Ion-pair reagents are incompatible with MS detection and add method complexity; Hypersil GOLD HILIC achieves polar analyte retention through the HILIC mechanism using simple volatile mobile phase additives (e.g., formic acid, ammonium formate) fully compatible with MS.


Q: What are the pore size, carbon load, and pH range of Hypersil GOLD HILIC?

Hypersil GOLD HILIC has a pore size of 175 Å, a carbon load of 6%, and a pH operating range of 2 to 8, as stated in the manufacturer's product literature. Always refer to the column care and use instructions supplied with your column for precise operating limits.


Q: What particle sizes are available for Hypersil GOLD HILIC?

Hypersil GOLD HILIC is available in three analytical particle sizes: 1.9 µm (UHPLC format), 3 µm (HPLC), and 5 µm (HPLC) — covering fast UHPLC methods through to standard analytical HPLC separations.


Q: What column lengths and internal diameters are available for Hypersil GOLD HILIC?

The 1.9 µm UHPLC format is available in 50–150 mm lengths in 2.1 mm ID only. The 3 µm format covers 30–150 mm lengths across 1.0, 2.1, 3.0, and 4.6 mm ID. The 5 µm format covers 50–250 mm lengths across 2.1, 3.0, and 4.6 mm ID. See the Variants & Ordering tab for the complete part number matrix.


Q: Is a guard column available for Hypersil GOLD HILIC?

Yes. Drop-in Guard cartridges (4/pk, 10 mm) are available for 3 µm columns in 1.0, 2.1, 3.0, and 4.6 mm ID, and for 5 µm columns in 2.1 and 4.6 mm ID. Uniguard Drop-in Guard Cartridge Holders are available: 851-00 (1.0 mm ID), 852-00 (2.1 mm / 3.0 mm ID), and 850-00 (4.6 mm ID).


Q: How does Hypersil GOLD HILIC compare to Accucore HILIC?

Both are designed for polar analyte retention in HILIC mode. Hypersil GOLD HILIC is built on fully porous silica particles (1.9, 3, 5 µm) with the Hypersil GOLD ultra-pure base-deactivated silica platform and a 6% carbon load. Accucore HILIC uses the 2.6 µm Fused Core (solid-core) particle architecture. The choice between them depends on whether Fused Core speed/efficiency or the Hypersil GOLD fully porous silica platform better suits the application workflow.


Q: Where can I buy Hypersil GOLD HILIC columns in Maharashtra?

Hypersil GOLD HILIC columns are available in Maharashtra through Subodh Trading Company, the authorized Thermo Fisher distributor for Maharashtra. Subodh Trading Company supplies genuine Thermo Fisher products with full warranty and Certificate of Analysis, serving laboratories across Pune, Nagpur, Nashik, Aurangabad, Chhatrapati Sambhaji Nagar, Solapur, Sangli, Kolhapur, Satara, Ahmednagar, Jalgaon, Nanded, Amravati, Akola, Latur, Ratnagiri, Thane, and all of Maharashtra. Contact: sales@subodhtrading.com.


Q: How do I obtain a Certificate of Analysis for my Hypersil GOLD HILIC column?

A Certificate of Analysis is available for every Hypersil GOLD HILIC column by part number and lot number from the Thermo Fisher CoA search portal at thermofisher.com. Subodh Trading Company can also assist customers in Maharashtra — email sales@subodhtrading.com with your purchase details or column lot number.

Have a question?

Need help selecting the right Hypersil GOLD HILIC?