Subodh Trading Company Logo

Quick Searches

Quote Cart

0 items selected

Hypersil Columns

Hypersil GOLD Phenyl

The Thermo Fisher™ Hypersil GOLD™ Phenyl column is a phenyl reversed-phase HPLC column built on 1.9, 3, and 5 µm particle sizes — engineered around a C4 linker that allows for superior alignment of the phenyl ring with aromatic molecules, delivering enhanced pi-pi interactions with aromatics that surpass what standard phenyl phases achieve. The C4 linker provides greater conformational flexibility than a direct-bonded phenyl, enabling the phenyl ring to orient more effectively toward aromatic analytes and maximise the pi-pi interaction contribution to retention and selectivity. Combined with moderate hydrophobicity and outstanding peak shape and sensitivity, Hypersil GOLD Phenyl is designed as a highly capable orthogonal selectivity tool for aromatic pharmaceutical compounds, antidepressants, phthalates, and structurally diverse analytes that benefit from a phenyl phase selectivity profile. Classified under USP L11 with a pore size of 175 Å, a carbon load of 8%, and a pH range of 2 to 8, available in column lengths of 50–250 mm across 1.0, 2.1, 3.0, and 4.6 mm internal diameters.

Price
Contact for pricing

Hypersil GOLD Phenyl Hypersil Columns Technical Specifications and Details

Hypersil GOLD Phenyl — C4-Linked Phenyl Phase With Enhanced Pi-Pi Aromatic Selectivity

Superior Phenyl-Aromatic Alignment Through C4 Linker Design

Standard phenyl reversed-phase columns bond the phenyl ring directly to the silica surface through a short propyl or similar linker — which can restrict the conformational freedom of the phenyl ring and limit its ability to align optimally with aromatic analytes. Hypersil GOLD Phenyl addresses this through a C4 linker design that allows for superior alignment of the phenyl ring with aromatic molecules, maximising the pi-pi interaction contribution and delivering enhanced aromatic selectivity compared to shorter-linked phenyl phases.

This enhanced pi-pi interaction — combined with moderate hydrophobicity and outstanding peak shape and sensitivity from the Hypersil GOLD ultra-pure silica platform — makes Hypersil GOLD Phenyl a powerful choice for aromatic compound analysis and a versatile orthogonal selectivity option alongside C18 methods.

Hypersil GOLD Phenyl Column — Product Image Hypersil GOLD Phenyl — 1.9, 3, and 5 µm particle sizes, USP L11, 175 Å pore size, 8% carbon load, pH 2–8.


Key Benefits

  • C4 linker for superior phenyl ring alignment — engineered for maximum pi-pi interaction between the phenyl ring and aromatic analyte molecules
  • Enhanced pi-pi interactions with aromatics — stronger aromatic selectivity than short-linker phenyl phases; differentiates structurally similar aromatic compounds
  • Moderate hydrophobicity — retains a useful reversed-phase hydrophobic contribution alongside the pi-pi selectivity
  • Outstanding peak shape and sensitivity — ultra-pure silica endcapping delivers sharp, symmetrical peaks across basic, neutral, and acidic analytes
  • Three particle sizes — 1.9 µm (UHPLC), 3 µm, and 5 µm covering the full range of HPLC and UHPLC workflows
  • USP L11 classification — supports pharmacopoeial method compliance

Hypersil GOLD Phenyl vs. Hypersil GOLD PFP — Choosing the Right Aromatic Phase

Feature Hypersil GOLD PFP Hypersil GOLD Phenyl
Phase Type Pentafluorophenyl C4-linked phenyl
Pi-pi interactions Enhanced via fluorine electron-withdrawal Enhanced via C4-linked superior ring alignment
Halogenated species retention Extra retention Not specifically enhanced
Polar compound selectivity Specific polar selectivity Moderate hydrophobicity
Best for Halogenated compounds, tri-modal selectivity Aromatic compounds, antidepressants, phthalates
Carbon Load 8% 8%
USP Classification L43 L11

Chromatographic Demonstration — Antidepressants

The chromatogram below demonstrates Hypersil GOLD Phenyl resolving eight structurally diverse analytes including antidepressants, hydroxylated compounds, and phthalates — a compound class mixture that benefits from the combined pi-pi and hydrophobic selectivity of the phenyl phase.

Hypersil GOLD Phenyl — Antidepressants Chromatogram Hypersil GOLD Phenyl, 1.9 µm, 50 × 2.1 mm. Mobile Phase A: 0.1% Formic acid. Mobile Phase B: 0.1% Formic acid in MeCN. Gradient: 10–60% B in 3.4 min, 60–90% B in 0.24 min. Temperature: 60°C. Flow Rate: 0.5 mL/min. Injection Volume: 0.7 µL. Detection: UV 225 and 254 nm.

Peak Assignment — Antidepressants and Related Analytes:

Peak Analyte
1 Uracil
2 Acetaminophen
3 p-Hydroxybenzoic acid
4 o-Hydroxybenzoic acid
imp Impurity
5 Oxazepam
6 Diazepam
7 Di-isopropyl phthalate
8 Di-n-propyl phthalate

Applications

Industry / Field Application
💊 Pharmaceutical Antidepressant drug assays, benzodiazepine analysis, hydroxylated pharmaceutical impurity profiling
🌿 Environmental Phthalate ester analysis, aromatic environmental contaminant screening
🔬 General Chemistry Aromatic compound separations where C18 provides insufficient selectivity differentiation
🧪 Food Science Aromatic preservative and additive analysis
🧬 Bioanalysis Aromatic drug compound quantification in biological matrices

Phase Property Overview

Property Value / Description
Phase Chemistry C4-linked phenyl — reversed phase with enhanced pi-pi aromatic interaction
Particle Sizes 1.9 µm, 3 µm, 5 µm
Pore Size 175 Å
Carbon Load 8%
pH Operating Range 2 to 8
Hydrophobicity Moderate (as indicated in manufacturer phase property chart)
USP Classification L11
Key Design Feature C4 linker for superior phenyl ring alignment with aromatic molecules

Column Format Overview

Format Particle Size Lengths Available Internal Diameters
UHPLC Column 1.9 µm 50, 100, 150, 200 mm 2.1, 3.0, 4.6 mm
HPLC Column 3 µm 50, 100, 150 mm 1.0, 2.1, 3.0, 4.6 mm
HPLC Column 5 µm 50, 100, 150, 250 mm 2.1, 3.0, 4.6 mm
Drop-in Guard (4/pk) 3 µm 10 mm 2.1, 3.0, 4.6 mm
Drop-in Guard (4/pk) 5 µm 10 mm 2.1, 3.0, 4.6 mm
Uniguard Drop-in Guard Cartridge Holder 10 mm 1.0, 2.1, 3.0, 4.6 mm

Hypersil GOLD Phenyl — Variants & Ordering Guide

Hypersil GOLD Phenyl is available in three analytical particle sizes — 1.9, 3, and 5 µm — across a range of column lengths and internal diameters, plus Drop-in Guard and Uniguard accessories.

Hypersil GOLD Phenyl Column Formats


Particle Size: 1.9 µm — UHPLC Column

Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.6 mm ID
50 25902-052130 25902-054630
100 25902-102130 25902-103030
150 25902-152130
200 25902-202130

Particle Size: 3 µm — Drop-in Guard (4/pk) & HPLC Column

Format Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.6 mm ID
Drop-in Guard (4/pk) 10 25903-012101 25903-013001 25903-014001
HPLC Column 50 25903-052130 25903-053030
HPLC Column 100 25903-102130 25903-103030 25903-104630
HPLC Column 150 25903-151030 25905-152130 25903-153030 25903-154630

Particle Size: 5 µm — Drop-in Guard (4/pk) & HPLC Column

Format Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.6 mm ID
Drop-in Guard (4/pk) 10 25905-012101 25905-013001 25905-014001
HPLC Column 50 25905-052130 25905-054630
HPLC Column 100 25905-102130 25905-103030 25905-104630
HPLC Column 150 25905-152130 25905-154630
HPLC Column 250 25905-254630

Uniguard Drop-in Guard Cartridge Holder

Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.6 mm ID
10 851-00 852-00 852-00 850-00

Dashes (—) indicate that format/dimension combination is not listed in current product literature.


📧 Subodh Trading Company — Authorized Thermo Fisher Distributor, Maharashtra > sales@subodhtrading.com

Technical Specifications — Hypersil GOLD Phenyl

Phase & Chemical Properties

Property Value / Description
Phase Chemistry C4-linked phenyl — reversed phase with enhanced pi-pi aromatic interaction
Particle Sizes 1.9 µm, 3 µm, 5 µm
Pore Size 175 Å
Carbon Load 8%
pH Operating Range 2 to 8
Hydrophobicity Moderate (as indicated in manufacturer phase property chart)
USP Classification L11
Key Design Feature C4 linker allows superior alignment of phenyl ring with aromatic molecules

Hypersil GOLD Phenyl Phase Properties


Demonstrated Method Conditions — Antidepressants Application

Parameter Value
Column Hypersil GOLD Phenyl, 1.9 µm, 50 × 2.1 mm
Mobile Phase A 0.1% Formic acid
Mobile Phase B 0.1% Formic acid in MeCN
Gradient 10–60% B in 3.4 min; 60–90% B in 0.24 min
Temperature 60°C
Flow Rate 0.5 mL/min
Injection Volume 0.7 µL
Detection UV 225 and 254 nm
Analytes 1. Uracil, 2. Acetaminophen, 3. p-Hydroxybenzoic acid, 4. o-Hydroxybenzoic acid, imp. Impurity, 5. Oxazepam, 6. Diazepam, 7. Di-isopropyl phthalate, 8. Di-n-propyl phthalate

Conditions taken directly from manufacturer application chromatogram legend. Not intended as universal method recommendations for all sample types or instruments.


Column Dimensions Reference — 1.9 µm UHPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25902-052130 UHPLC Column 50 2.1 1.9 Phenyl
25902-054630 UHPLC Column 50 4.6 1.9 Phenyl
25902-102130 UHPLC Column 100 2.1 1.9 Phenyl
25902-103030 UHPLC Column 100 3.0 1.9 Phenyl
25902-152130 UHPLC Column 150 2.1 1.9 Phenyl
25902-202130 UHPLC Column 200 2.1 1.9 Phenyl

Column Dimensions Reference — 3 µm HPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25903-012101 Drop-in Guard (4/pk) 10 2.1 3 Phenyl
25903-013001 Drop-in Guard (4/pk) 10 3.0 3 Phenyl
25903-014001 Drop-in Guard (4/pk) 10 4.6 3 Phenyl
25903-052130 HPLC Column 50 2.1 3 Phenyl
25903-053030 HPLC Column 50 3.0 3 Phenyl
25903-102130 HPLC Column 100 2.1 3 Phenyl
25903-103030 HPLC Column 100 3.0 3 Phenyl
25903-104630 HPLC Column 100 4.6 3 Phenyl
25903-151030 HPLC Column 150 1.0 3 Phenyl
25905-152130 HPLC Column 150 2.1 3 Phenyl
25903-153030 HPLC Column 150 3.0 3 Phenyl
25903-154630 HPLC Column 150 4.6 3 Phenyl

Column Dimensions Reference — 5 µm HPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25905-012101 Drop-in Guard (4/pk) 10 2.1 5 Phenyl
25905-013001 Drop-in Guard (4/pk) 10 3.0 5 Phenyl
25905-014001 Drop-in Guard (4/pk) 10 4.6 5 Phenyl
25905-052130 HPLC Column 50 2.1 5 Phenyl
25905-054630 HPLC Column 50 4.6 5 Phenyl
25905-102130 HPLC Column 100 2.1 5 Phenyl
25905-103030 HPLC Column 100 3.0 5 Phenyl
25905-104630 HPLC Column 100 4.6 5 Phenyl
25905-152130 HPLC Column 150 2.1 5 Phenyl
25905-154630 HPLC Column 150 4.6 5 Phenyl
25905-254630 HPLC Column 250 4.6 5 Phenyl

Uniguard Drop-in Guard Cartridge Holder

Cat. No. Length (mm) ID
851-00 10 1.0 mm
852-00 10 2.1 mm / 3.0 mm
850-00 10 4.6 mm

⚠️ Specifications and performance data presented here are based on publicly available manufacturer literature. Performance may vary based on application conditions, instrument configuration, and sample matrix. For method-specific guidance, contact Subodh Trading Company at sales@subodhtrading.com — authorized Thermo Fisher distributor for Maharashtra.

FAQs — Hypersil GOLD Phenyl Column


Q: What is the Hypersil GOLD Phenyl column and what is it used for?

Hypersil GOLD Phenyl is a C4-linked phenyl reversed-phase HPLC column engineered for enhanced pi-pi interactions with aromatic molecules, moderate hydrophobicity, and outstanding peak shape and sensitivity. It is designed for antidepressant and benzodiazepine analysis, phthalate ester separations, hydroxylated pharmaceutical compound profiling, and any application where a phenyl phase selectivity profile provides better resolution of aromatic analytes than standard C18.


Q: What is the role of the C4 linker in Hypersil GOLD Phenyl?

The C4 linker connects the phenyl ring to the silica surface with greater conformational flexibility than a short direct-bonded linker. This allows the phenyl ring to align more effectively with aromatic analyte molecules — maximising the pi-pi interaction contribution to retention and selectivity. The result is enhanced aromatic selectivity compared to phenyl phases with shorter or more rigid linker chemistry.


Q: How does Hypersil GOLD Phenyl differ from Hypersil GOLD PFP?

Both phases provide enhanced pi-pi interactions with aromatics, but through different mechanisms. Hypersil GOLD PFP uses fluorine substituents on the phenyl ring to increase electron deficiency and enhance pi-pi interaction, while also providing halogen affinity and specific polar compound selectivity — giving it a tri-modal selectivity profile. Hypersil GOLD Phenyl uses the C4 linker for superior ring alignment and provides moderate hydrophobicity alongside pi-pi selectivity. For purely aromatic applications, either phase may be suitable; for halogenated compounds, Hypersil GOLD PFP is preferred.


Q: What analytes were demonstrated in the antidepressants application chromatogram?

Eight analytes were separated: Uracil, Acetaminophen, p-Hydroxybenzoic acid, o-Hydroxybenzoic acid, an impurity peak, Oxazepam, Diazepam, Di-isopropyl phthalate, and Di-n-propyl phthalate — on Hypersil GOLD Phenyl, 1.9 µm, 50 × 2.1 mm under a fast gradient UHPLC method. All conditions are sourced directly from the manufacturer's application chromatogram legend.


Q: What method conditions were used in the antidepressants chromatogram?

Column — Hypersil GOLD Phenyl, 1.9 µm, 50 × 2.1 mm; Mobile Phase A — 0.1% Formic acid; Mobile Phase B — 0.1% Formic acid in MeCN; Gradient — 10–60% B in 3.4 min, 60–90% B in 0.24 min; Temperature — 60°C; Flow Rate — 0.5 mL/min; Injection Volume — 0.7 µL; Detection — UV 225 and 254 nm. All values are sourced directly from the manufacturer's application chromatogram legend.


Q: What USP classification does Hypersil GOLD Phenyl carry?

Hypersil GOLD Phenyl is classified under USP L11, as stated in the manufacturer's product literature. This supports its use in pharmacopoeial methods and regulated laboratory workflows specifying a USP L11 phenyl stationary phase.


Q: What are the pore size, carbon load, and pH range of Hypersil GOLD Phenyl?

Hypersil GOLD Phenyl has a pore size of 175 Å, a carbon load of 8%, and a pH operating range of 2 to 8, as stated in the manufacturer's product literature. Always refer to the column care and use instructions supplied with your column for precise operating limits.


Q: What particle sizes are available for Hypersil GOLD Phenyl?

Hypersil GOLD Phenyl is available in three analytical particle sizes: 1.9 µm (UHPLC format), 3 µm (HPLC), and 5 µm (HPLC) — covering fast UHPLC methods through to standard analytical HPLC separations.


Q: What column lengths and internal diameters are available for Hypersil GOLD Phenyl?

The 1.9 µm UHPLC format is available in 50–200 mm lengths across 2.1, 3.0, and 4.6 mm ID. The 3 µm format covers 50–150 mm lengths across 1.0, 2.1, 3.0, and 4.6 mm ID. The 5 µm format covers 50–250 mm lengths across 2.1, 3.0, and 4.6 mm ID. Not all length and ID combinations are available for every particle size — see the Variants & Ordering tab for the complete matrix.


Q: Is a guard column available for Hypersil GOLD Phenyl?

Yes. Drop-in Guard cartridges (4/pk, 10 mm) are available for 3 µm columns in 2.1, 3.0, and 4.6 mm ID, and for 5 µm columns in 2.1, 3.0, and 4.6 mm ID. Uniguard Drop-in Guard Cartridge Holders are available: 851-00 (1.0 mm ID), 852-00 (2.1 mm / 3.0 mm ID), and 850-00 (4.6 mm ID).


Q: Can Hypersil GOLD Phenyl be used as an orthogonal selectivity column alongside C18?

Yes. Hypersil GOLD Phenyl provides a different selectivity mechanism from C18 — driven by pi-pi interaction and moderate hydrophobicity rather than purely hydrophobic retention. For complex aromatic mixtures where C18 co-elutes compounds, Hypersil GOLD Phenyl often resolves the co-eluting pairs. It is well suited as a second column in orthogonal method development alongside Hypersil GOLD C18.


Q: Where can I buy Hypersil GOLD Phenyl columns in Maharashtra?

Hypersil GOLD Phenyl columns are available in Maharashtra through Subodh Trading Company, the authorized Thermo Fisher distributor for Maharashtra. Subodh Trading Company supplies genuine Thermo Fisher products with full warranty and Certificate of Analysis, serving laboratories across Pune, Nagpur, Nashik, Aurangabad, Chhatrapati Sambhaji Nagar, Solapur, Sangli, Kolhapur, Satara, Ahmednagar, Jalgaon, Nanded, Amravati, Akola, Latur, Ratnagiri, Thane, and all of Maharashtra. Contact: sales@subodhtrading.com.


Q: How do I obtain a Certificate of Analysis for my Hypersil GOLD Phenyl column?

A Certificate of Analysis is available for every Hypersil GOLD Phenyl column by part number and lot number from the Thermo Fisher CoA search portal at thermofisher.com. Subodh Trading Company can also assist customers in Maharashtra — email sales@subodhtrading.com with your purchase details or column lot number.

Have a question?

Need help selecting the right Hypersil GOLD Phenyl?