The Thermo Fisher™ Hypersil GOLD™ Silica column is an unbonded, highly pure base-deactivated silica HPLC column built on 1.9, 3, and 5 µm particle sizes — the same ultra-pure silica backbone that underpins the entire Hypersil GOLD range of bonded phase columns. As an unbonded silica phase, it is engineered for normal-phase separations, providing adsorption-based retention through free silanol interactions for polar compound classes including steroids, lipids, fat-soluble vitamins, and structurally related isomers that require normal-phase selectivity for resolution. The highly pure base-deactivated silica minimizes non-specific secondary interactions — a key source of peak tailing and irreproducibility on conventional silica columns — delivering outstanding peak shape and sensitivity that distinguishes Hypersil GOLD Silica from standard unbonded silica phases. Classified under USP L3 with a pore size of 175 Å, a pH range of 2 to 8, and negligible carbon load, available in column lengths of 30–250 mm across 1.0, 2.1, 3.0, 4.0, and 4.6 mm internal diameters.

Price
Contact for pricing

Hypersil GOLD Silica Hypersil Columns Technical Specifications and Details

Hypersil GOLD Silica — Ultra-Pure Base-Deactivated Silica for Normal-Phase Separations

The Same Pure Silica Foundation — Now in Unbonded Normal-Phase Format

Every column in the Hypersil GOLD range is built on the same ultra-pure base-deactivated silica backbone — engineered to minimize residual silanol activity, reduce peak tailing, and deliver the consistent, reproducible performance that defines the Hypersil GOLD platform. Hypersil GOLD Silica makes this same highly pure silica foundation available as an unbonded normal-phase column — bringing the peak shape and sensitivity advantages of the Hypersil GOLD platform to normal-phase applications.

Unbonded silica provides adsorption-based retention through polar interaction with surface silanol groups, making it the classic choice for normal-phase separations of steroids, lipids, fat-soluble vitamins, and structurally related polar isomers. The highly pure base-deactivated silica of Hypersil GOLD Silica minimizes the non-specific secondary interactions that cause peak tailing and poor reproducibility on conventional silica columns.

Hypersil GOLD Silica Column — Product Image Hypersil GOLD Silica — Unbonded highly pure base-deactivated silica, USP L3, 175 Å pore size, 1.9, 3, and 5 µm particle sizes, pH 2–8.


Key Benefits

  • Highly pure base-deactivated silica — the backbone of the entire Hypersil GOLD column range, now in unbonded normal-phase format
  • Outstanding peak shape and sensitivity — ultra-pure silica minimizes secondary silanol interactions that cause peak tailing on conventional silica columns
  • Normal-phase adsorption selectivity — ideal for steroids, lipids, fat-soluble vitamins, and polar isomers requiring normal-phase resolution
  • Three particle sizes — 1.9 µm (UHPLC), 3 µm, and 5 µm for the full range of HPLC and UHPLC workflows
  • USP L3 classification — supports pharmacopoeial method compliance for methods specifying an unbonded silica stationary phase

When to Use Hypersil GOLD Silica vs. Bonded Normal-Phase Phases

Criteria Hypersil GOLD CN or Amino (Bonded NP) Hypersil GOLD Silica (Unbonded)
Stationary phase type Bonded polar phase Unbonded silica — free silanols
Retention mechanism Dipole-dipole / hydrogen bond via bonded group Adsorption via silanol interaction
Selectivity Modified by bonded group Classic normal-phase silica selectivity
Reproducibility Higher — less sensitive to water content Must control mobile phase water content
Best for Routine normal-phase method development Traditional normal-phase applications; steroid, lipid, fat-soluble vitamin separations
USP Classification L10 (CN) / L8 (Amino) L3

Chromatographic Demonstration — Steroids

The chromatogram below demonstrates Hypersil GOLD Silica separating seven structurally related steroid analytes under normal-phase conditions — a compound class for which silica adsorption-based normal-phase selectivity is the established analytical approach.

Hypersil GOLD Silica — Steroids Normal-Phase Chromatogram Hypersil GOLD Silica, 5 µm, 150 × 4.6 mm. Mobile Phase: 19:1 (v/v) n-C6H14 : EtOH. Temperature: 30°C. Flow Rate: 1.5 mL/min. Injection Volume: 5 µL. Detection: UV 254 nm.

Peak Assignment — Steroids:

Peak Analyte
1 Progesterone
2 21-Hydroxyprogesterone-21-acetate
3 17-a-Hydroxyprogesterone
4 Cortisone
5 11-a-Hydroxyprogesterone
6 Corticosterone
7 Hydrocortisone

Applications

Industry / Field Application
💊 Pharmaceutical Steroid API and impurity profiling, fat-soluble vitamin assays, pharmacopoeial normal-phase methods
🌿 Food Science & Nutrition Fat-soluble vitamin and carotenoid analysis in normal-phase mode
🔬 Biochemistry Lipid class separation, steroid hormone profiling
🧪 General Chemistry Polar isomeric compound separation requiring classic silica adsorption selectivity
🌿 Environmental Non-polar to moderately polar compound class fractionation in normal-phase mode

Phase Property Overview

Property Value / Description
Phase Chemistry Unbonded silica — highly pure base-deactivated
Particle Sizes 1.9 µm, 3 µm, 5 µm
Pore Size 175 Å
Carbon Load Negligible (unbonded — as indicated in manufacturer phase property chart)
pH Operating Range 2 to 8
Hydrophobicity Very low (as indicated in manufacturer phase property chart)
Operating Mode Normal phase
USP Classification L3
Key Differentiator Same ultra-pure base-deactivated silica backbone as bonded Hypersil GOLD phases

Column Format Overview

Format Particle Size Lengths Available Internal Diameters
UHPLC Column 1.9 µm 50, 100, 150, 200 mm 2.1 mm
HPLC Column 3 µm 30, 100, 150 mm 1.0, 2.1, 3.0, 4.6 mm
HPLC Column 5 µm 50, 100, 150, 250 mm 2.1, 3.0, 4.0, 4.6 mm
Drop-in Guard (4/pk) 3 µm 10 mm 1.0, 2.1, 3.0, 4.6 mm
Drop-in Guard (4/pk) 5 µm 10 mm 2.1, 4.0, 4.6 mm
Uniguard Drop-in Guard Cartridge Holder 10 mm 1.0, 2.1, 3.0, 4.0, 4.6 mm

Hypersil GOLD Silica — Variants & Ordering Guide

Hypersil GOLD Silica is available in three analytical particle sizes — 1.9, 3, and 5 µm — across a range of column lengths and internal diameters, plus Drop-in Guard and Uniguard accessories.

Hypersil GOLD Silica Column Formats


Particle Size: 1.9 µm — UHPLC Column

Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.0 mm ID 4.6 mm ID
50 25102-052130
100 25102-102130
150 25102-152130
200 25102-202130

Particle Size: 3 µm — Drop-in Guard (4/pk) & HPLC Column

Format Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.0 mm ID 4.6 mm ID
Drop-in Guard (4/pk) 10 25103-011001 25103-012101 25103-013001 25103-014001
HPLC Column 30 25103-032130 25103-034630
HPLC Column 100 25103-102130 25101-104630
HPLC Column 150 25103-152130 25103-153030 25103-154630

Particle Size: 5 µm — Drop-in Guard (4/pk) & HPLC Column

Format Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.0 mm ID 4.6 mm ID
Drop-in Guard (4/pk) 10 25105-012101 25105-014001 25105-014001
HPLC Column 50 25105-052130 25105-054630
HPLC Column 100 25105-102130 25105-103030 25105-104630
HPLC Column 150 25105-152130 25105-154630
HPLC Column 250 25105-252130 25105-254030 25105-254630

Uniguard Drop-in Guard Cartridge Holder

Length (mm) 1.0 mm ID 2.1 mm ID 3.0 mm ID 4.0 mm ID 4.6 mm ID
10 851-00 852-00 852-00 850-00 850-00

Dashes (—) indicate that format/dimension combination is not listed in current product literature.


📧 Subodh Trading Company — Authorized Thermo Fisher Distributor, Maharashtra > sales@subodhtrading.com

Technical Specifications — Hypersil GOLD Silica

Phase & Chemical Properties

Property Value / Description
Phase Chemistry Unbonded silica — highly pure base-deactivated
Particle Sizes 1.9 µm, 3 µm, 5 µm
Pore Size 175 Å
Carbon Load Negligible (unbonded — as indicated in manufacturer phase property chart)
pH Operating Range 2 to 8
Hydrophobicity Very low (as indicated in manufacturer phase property chart)
Operating Mode Normal phase
USP Classification L3

Hypersil GOLD Silica Phase Properties


Demonstrated Method Conditions — Steroids Application

Parameter Value
Column Hypersil GOLD Silica, 5 µm, 150 × 4.6 mm
Mobile Phase 19:1 (v/v) n-C6H14 : EtOH
Temperature 30°C
Flow Rate 1.5 mL/min
Injection Volume 5 µL
Detection UV, 254 nm
Analytes 1. Progesterone, 2. 21-Hydroxyprogesterone-21-acetate, 3. 17-a-Hydroxyprogesterone, 4. Cortisone, 5. 11-a-Hydroxyprogesterone, 6. Corticosterone, 7. Hydrocortisone

Conditions taken directly from manufacturer application chromatogram legend. Not intended as universal method recommendations for all sample types or instruments.


Column Dimensions Reference — 1.9 µm UHPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25102-052130 UHPLC Column 50 2.1 1.9 Silica
25102-102130 UHPLC Column 100 2.1 1.9 Silica
25102-152130 UHPLC Column 150 2.1 1.9 Silica
25102-202130 UHPLC Column 200 2.1 1.9 Silica

Column Dimensions Reference — 3 µm HPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25103-011001 Drop-in Guard (4/pk) 10 1.0 3 Silica
25103-012101 Drop-in Guard (4/pk) 10 2.1 3 Silica
25103-013001 Drop-in Guard (4/pk) 10 3.0 3 Silica
25103-014001 Drop-in Guard (4/pk) 10 4.6 3 Silica
25103-032130 HPLC Column 30 2.1 3 Silica
25103-034630 HPLC Column 30 4.6 3 Silica
25103-102130 HPLC Column 100 2.1 3 Silica
25101-104630 HPLC Column 100 4.6 3 Silica
25103-152130 HPLC Column 150 2.1 3 Silica
25103-153030 HPLC Column 150 3.0 3 Silica
25103-154630 HPLC Column 150 4.6 3 Silica

Column Dimensions Reference — 5 µm HPLC

Cat. No. Format Length (mm) ID (mm) Particle (µm) Phase
25105-012101 Drop-in Guard (4/pk) 10 2.1 5 Silica
25105-014001 Drop-in Guard (4/pk) 10 4.0 / 4.6 5 Silica
25105-052130 HPLC Column 50 2.1 5 Silica
25105-054630 HPLC Column 50 4.6 5 Silica
25105-102130 HPLC Column 100 2.1 5 Silica
25105-103030 HPLC Column 100 3.0 5 Silica
25105-104630 HPLC Column 100 4.6 5 Silica
25105-152130 HPLC Column 150 2.1 5 Silica
25105-154630 HPLC Column 150 4.6 5 Silica
25105-252130 HPLC Column 250 2.1 5 Silica
25105-254030 HPLC Column 250 4.0 5 Silica
25105-254630 HPLC Column 250 4.6 5 Silica

Uniguard Drop-in Guard Cartridge Holder

Cat. No. Length (mm) ID
851-00 10 1.0 mm
852-00 10 2.1 mm / 3.0 mm
850-00 10 4.0 mm / 4.6 mm

⚠️ Specifications and performance data presented here are based on publicly available manufacturer literature. Performance may vary based on application conditions, instrument configuration, and sample matrix. For method-specific guidance, contact Subodh Trading Company at sales@subodhtrading.com — authorized Thermo Fisher distributor for Maharashtra.

FAQs — Hypersil GOLD Silica Column


Q: What is the Hypersil GOLD Silica column and what is it used for?

Hypersil GOLD Silica is an unbonded, highly pure base-deactivated silica normal-phase HPLC column — the same ultra-pure silica backbone that underpins the entire Hypersil GOLD bonded phase range. It is designed for normal-phase adsorption separations of steroids, lipids, fat-soluble vitamins, polar isomers, and other compound classes where normal-phase silica selectivity provides the required resolution. Outstanding peak shape and sensitivity distinguish it from conventional silica columns.


Q: What makes Hypersil GOLD Silica different from a standard unbonded silica column?

Hypersil GOLD Silica is built on the same highly pure base-deactivated silica that forms the backbone of all Hypersil GOLD columns. Standard silica columns typically have a higher level of residual silanol activity — particularly acidic silanols — that cause non-specific secondary interactions, peak tailing, and poor reproducibility. The Hypersil GOLD base-deactivation process is engineered to minimize these interactions, delivering outstanding peak shape and sensitivity that standard silica phases do not achieve.


Q: What separations is Hypersil GOLD Silica best suited for?

Hypersil GOLD Silica is best suited for normal-phase separations of steroids and steroid hormones, lipid class separations, fat-soluble vitamins, and any application requiring silica adsorption selectivity for polar isomers. It is the column of choice when classic normal-phase silica selectivity is required and bonded normal-phase phases (CN, amino) do not provide the required resolution or selectivity profile.


Q: What analytes were demonstrated in the steroids chromatogram?

Seven steroid analytes were separated in normal-phase mode: Progesterone, 21-Hydroxyprogesterone-21-acetate, 17-a-Hydroxyprogesterone, Cortisone, 11-a-Hydroxyprogesterone, Corticosterone, and Hydrocortisone — on Hypersil GOLD Silica, 5 µm, 150 × 4.6 mm, using 19:1 (v/v) hexane:ethanol mobile phase at 1.5 mL/min, 30°C, with UV detection at 254 nm. All conditions are sourced directly from the manufacturer's application chromatogram legend.


Q: What method conditions were used in the steroids chromatogram?

Column — Hypersil GOLD Silica, 5 µm, 150 × 4.6 mm; Mobile Phase — 19:1 (v/v) n-C6H14 : EtOH; Temperature — 30°C; Flow Rate — 1.5 mL/min; Injection Volume — 5 µL; Detection — UV 254 nm. All values are sourced directly from the manufacturer's application chromatogram legend.


Q: What USP classification does Hypersil GOLD Silica carry?

Hypersil GOLD Silica is classified under USP L3, as stated in the manufacturer's product literature. This supports its use in pharmacopoeial methods and regulated laboratory workflows specifying an unbonded silica stationary phase under USP L3.


Q: What is the pore size and pH range of Hypersil GOLD Silica?

Hypersil GOLD Silica has a pore size of 175 Å and a pH operating range of 2 to 8, as stated in the manufacturer's product literature. Always refer to the column care and use instructions for precise operating limits.


Q: How does Hypersil GOLD Silica compare to Hypersil GOLD CN or Amino in normal-phase mode?

All three can be used in normal-phase mode, but through different mechanisms. Hypersil GOLD Silica provides classic silica adsorption selectivity through direct silanol interaction — the traditional normal-phase mechanism. Hypersil GOLD CN and Amino provide polar interaction through their bonded groups, which modifies selectivity and generally improves reproducibility since bonded phases are less sensitive to mobile phase water content. Silica is preferred when classic adsorption selectivity is specifically required or when matching existing normal-phase silica methods.


Q: What particle sizes are available for Hypersil GOLD Silica?

Hypersil GOLD Silica is available in three analytical particle sizes: 1.9 µm (UHPLC format), 3 µm (HPLC), and 5 µm (HPLC) — covering fast UHPLC methods through to standard analytical HPLC separations.


Q: What column lengths and internal diameters are available for Hypersil GOLD Silica?

The 1.9 µm UHPLC format is available in 50–200 mm lengths in 2.1 mm ID only. The 3 µm format covers 30–150 mm lengths across 1.0, 2.1, 3.0, and 4.6 mm ID — note there is no 50 mm listed for 3 µm. The 5 µm format covers 50–250 mm lengths across 2.1, 3.0, 4.0, and 4.6 mm ID. See the Variants & Ordering tab for the complete part number matrix.


Q: Is a guard column available for Hypersil GOLD Silica?

Yes. Drop-in Guard cartridges (4/pk, 10 mm) are available for 3 µm columns in 1.0, 2.1, 3.0, and 4.6 mm ID, and for 5 µm columns in 2.1, 4.0, and 4.6 mm ID. Uniguard Drop-in Guard Cartridge Holders are available: 851-00 (1.0 mm ID), 852-00 (2.1 mm / 3.0 mm ID), and 850-00 (4.0 mm / 4.6 mm ID).


Q: Where can I buy Hypersil GOLD Silica columns in Maharashtra?

Hypersil GOLD Silica columns are available in Maharashtra through Subodh Trading Company, the authorized Thermo Fisher distributor for Maharashtra. Subodh Trading Company supplies genuine Thermo Fisher products with full warranty and Certificate of Analysis, serving laboratories across Pune, Nagpur, Nashik, Aurangabad, Chhatrapati Sambhaji Nagar, Solapur, Sangli, Kolhapur, Satara, Ahmednagar, Jalgaon, Nanded, Amravati, Akola, Latur, Ratnagiri, Thane, and all of Maharashtra. Contact: sales@subodhtrading.com.


Q: How do I obtain a Certificate of Analysis for my Hypersil GOLD Silica column?

A Certificate of Analysis is available for every Hypersil GOLD Silica column by part number and lot number from the Thermo Fisher CoA search portal at thermofisher.com. Subodh Trading Company can also assist customers in Maharashtra — email sales@subodhtrading.com with your purchase details or column lot number.

Have a question?

Need help selecting the right Hypersil GOLD Silica?